Your Page Title Optional page text here.
page 1
page 2
page 3
page 4
page 5
page 6
page 7
page 8
page 9
page 10
page 11
page 12
page 13
page 14
page 15
page 16
page 17
page 18
page 19
page 20
page 21
page 22
page 23
page 24
page 25
page 26
page 27
page 28
page 29
page 30
page 31
page 32
page 33
page 34
page 35
page 36
page 37
page 38
page 39
page 40
page 41
page 42
page 43
page 44
page 45
page 46
page 47
page 48
page 49
page 50
page 51
page 52
page 53
page 54
page 55
page 56
page 57
page 58
page 59
page 60
page 61
page 62
page 63
page 64
page 65
page 66
page 67
page 68
page 69
page 70
page 71
page 72
page 73
page 74
page 75
page 76
page 77
page 78
page 79
page 80
page 81
page 82
page 83
page 84
page 85
page 86
page 87
page 88
page 89
page 90
page 91
page 92
page 93
page 94
page 95
page 96
page 97
page 98
page 99
page 100
page 101
page 102
page 103
page 104
page 105
page 106
page 107
page 108
page 109
page 110
page 111
page 112
page 113
page 114
page 115
page 116
page 117
page 118
page 119
page 120
page 121
page 122
page 123
page 124
page 125
page 126
page 127
page 128
page 129
page 130
page 131
page 132
page 133
page 134
page 135
page 136
page 137
page 138
page 139
page 140
page 141
page 142
page 143
page 144
page 145
page 146
page 147
page 148
page 149
page 150
page 151
page 152
page 153
page 154
page 155
page 156
page 157
page 158
page 159
page 160
page 161
page 162
page 163
page 164
page 165
page 166
page 167
page 168
page 169
page 170
page 171
page 172
page 173
page 174
page 175
page 176
page 177
page 178
page 179
page 180
page 181
page 182
page 183
page 184
page 185
page 186
page 187
page 188
page 189
page 190
page 191
page 192
page 193
page 194
page 195
page 196
page 197
page 198
page 199
page 200
page 201
page 202
page 203
page 204
page 205
page 206
page 207
page 208
page 209
page 210
page 211
page 212
page 213
page 214
page 215
page 216

BAUDER MEMBRANE COLOUR OPTIONSThe Bauder Thermoplan and Thermofol single ply membranes each come in two colour options to suit the most popular preferences of specifiers for buildings constructed in today's market.Mechanical Fastening or Adhered SystemsAs with the insulation, the two main types of attachment methods can be adopted with the membrane itself. However to complicate matters a combination of the two types of attachment can be found is some systems dependant on deck type, aesthetic requirement, commercial consideration or project specifics.A general guide can be given here, but early discussion with your Bauder area technical manager can ensure the correct details for a specific project build up.Adhered SystemsThis option can be used effectively when the structural decking is either difficult to mechanically fasten into, or the use of fasteners will compromise the air leakage or internal aesthetics of the project. The adhered system can be used with either a fleece backed membrane or the standard non fleece backed membrane. Adhered systems still require an amount of mechanical restraint installed around the perimeter of the roof area, which is designed to assist in the resistance of wind uplift. The finished appearance of an adhered system is generally less wrinkled than that of a mechanically fastened system as the membrane is fully restrained over the whole roof surface, however the appearance will of course be affected by the substrate it is being installed on to.Mechanically FastenedThis option is generally used on most decking types, metal and timber being the most common. A concrete deck with a high proportion of stone can be difficult to mechanically fasten to, though it is possible if no other option is suitable. If this type of system is selected then consideration should be given to the aesthetic appearance of the protruding fasteners on the underside of the structural decking. The inclusion of an internal ceiling readily solves this issue.Mechanical fastening provides a fast safe and effective method of membrane attachment, but it is always recommended to undertake a wind uplift calculation to BS 6399 part 2 to ensure the correct fastener density is specified. Our technical department can provide these calculations within a project specification. Mechanical fastening is not affected by the ambient weather conditions or temperature and is therefore suitable for installation all year round.Fasteners Bauder requires that any fasteners used are tested and approved to UEAtc guidelines. Within our Thermoplan system we require the use of a tube and screw type fastener for both the attachment of the membrane and insulation. These types of fasteners provide a thermal brake in the system and reduce the transfer of heat from inside to out and are therefore far more thermally efficient than a standard type of fastener. For fasteners used in conjunction with our Thermofol system we recommend the use of tube and screw fasteners with guidance sought from the specialist supplier. Bauder only approves fasteners if they are supplied by companies who are associate members of the Single Ply Roofing Association (SPRA) and maintain that the performance of the fasteners selected must equal the total required by the whole system. 61 bauder.co.ukAdvantages of MECH FIX Disadvantages of MECH FIXCalculated to BS6399 Concrete needs pre-drillingFast track installation Membrane can tent or bagNot affected by adverse weather Fasteners visible on undersideor temperature of deckPRODUCTSilver GreyPearl WhiteLight GreyBlue GreyAnthraciteThermofolThermoplanDESCRIPTIONRAL NUMBERAdvantages of Adhered Disadvantages of AdheredNon penetration of vapour barrier Weather dependantNo internal aesthetic issues Cost and time of installationMembrane is fully restrained over Reduced possibilities of recyclingroof surfaceTECHNICALGUIDE70011013703570317016

SURFACE PROTECTIONbauder.ie62The life expectancy of a flat roof system is extended if it incorporates an aesthetic finish which provides protection of the membrane from the natural elements. This includes finishes such as ballast, paving or an extensive green roof.BALLASTED OR PAVEDThis particular finish is ideal where regular access is required such as on a roof terrace. It is also specified where wind uplift is a risk as the membrane is loose-laid and then held on the deck by the weight of the ballast or paving. If this type of surface protection is to be incorporated, it needs to be considered at the design stage as provision needs to be made for the supporting structural deck and the associated cost implications.WALKWAYS Clearly identified walkways should be installed from roof access points to areas of plant and equipment. Walkway material should be considered for use on all areas likely to carry foot traffic. Bauder walkway materials have a specially embossed anti slip finish as well as being a distinctive colour. Working platforms may be created by placing coated flat metal sheet on the surface of the insulation and mechanically fastened to the deck. The area should be waterproofed in the normal way and then walkway material placed onto the surface of the waterproofing and hot air welded into place.EXTENSIVE GREEN ROOFCreating an extensive green roof as a surface protection gives many environmental benefits and helps to mask the building into its surroundings, particularly if it is positioned in areas sensitive to construction. It uses low maintenance, frost and wind hardy vegetation, such as sedum plants. The roof is lightweight and cost effective, though it is not suitable for recreational use and should only be accessed for routine maintenance.Sedum Blanket Retention Spikes and SS40 TrimWhen single ply is used on sloped roofs over 5º with our Xeroflor sedum blanket it is necessary to install a Bauder retention spike system. The retention spikes are installed on to the top surface of the single ply membrane by a cover strap of membrane which is part welded through the large holes on the horizontal leg of the retention spike which is sat directly on to the surface of the membrane. On mechanically fastened single ply systems, a secondary line of fasteners is required between the two rows of fasteners within the side laps of the membrane sheets. This line of fasteners is positioned in the centre of the membrane sheet and runs at 90º to the retention spikes. These additional lines of fasteners must have a cover strap installed over them to provide weathering. This additional attachment is not required on adhered systems.When Bauder SS40 retention trim is required, it is installed onto the surface of the membrane and held in position by welding a cover strap of membrane through the large holes on the horizontal leg of the retention trim, which is sat directly on to the surface of the membrane.Extensive SubstrateExtensiveVegetation Paving SlabBallastDecking on Paver PadsDecking on Timber BearersT-SV 15 FSM 600llPF300llU15llFSM 600PF300FSM 600FSM 600U20llFSM 600PF300FSM 600FSM 600VllFSM 600PF300FSM 600FSM 600T-SV 12 FSM 600llPF300llT-SV 18 FSM 600llPF300llT-SV 20 FSM 600llPF300llT-SV FBFSM 600llPF300llTHERMOFOLl = not suitablel = suitable without the need for additional protection layerPF = Protection FleeceTHERMOPLAN