Your Page Title Optional page text here.
page 1
page 2
page 3
page 4
page 5
page 6
page 7
page 8
page 9
page 10
page 11
page 12
page 13
page 14
page 15
page 16
page 17
page 18
page 19
page 20
page 21
page 22
page 23
page 24
page 25
page 26
page 27
page 28
page 29
page 30
page 31
page 32
page 33
page 34
page 35
page 36
page 37
page 38
page 39
page 40
page 41
page 42
page 43
page 44
page 45
page 46
page 47
page 48
page 49
page 50
page 51
page 52
page 53
page 54
page 55
page 56
page 57
page 58
page 59
page 60
page 61
page 62
page 63
page 64
page 65
page 66
page 67
page 68
page 69
page 70
page 71
page 72
page 73
page 74
page 75
page 76
page 77
page 78
page 79
page 80
page 81
page 82
page 83
page 84
page 85
page 86
page 87
page 88
page 89
page 90
page 91
page 92
page 93
page 94
page 95
page 96
page 97
page 98
page 99
page 100
page 101
page 102
page 103
page 104
page 105
page 106
page 107
page 108
page 109
page 110
page 111
page 112
page 113
page 114
page 115
page 116
page 117
page 118
page 119
page 120
page 121
page 122
page 123
page 124
page 125
page 126
page 127
page 128
page 129
page 130
page 131
page 132
page 133
page 134
page 135
page 136
page 137
page 138
page 139
page 140
page 141
page 142
page 143
page 144
page 145
page 146
page 147
page 148
page 149
page 150
page 151
page 152
page 153
page 154
page 155
page 156
page 157
page 158
page 159
page 160
page 161
page 162
page 163
page 164
page 165
page 166
page 167
page 168
page 169
page 170
page 171
page 172
page 173
page 174
page 175
page 176
page 177
page 178
page 179
page 180
page 181
page 182
page 183
page 184
page 185
page 186
page 187
page 188
page 189
page 190
page 191
page 192
page 193
page 194
page 195
page 196
page 197
page 198
page 199
page 200
page 201
page 202
page 203
page 204
page 205
page 206
page 207
page 208
page 209
page 210
page 211
page 212
page 213
page 214
page 215
page 216

THERMAL DESIGNThermal design is concerned with the flow of both heat and water vapour through the roof construction and their subsequent effect on the performance of the roof and the various components in the system. The designer therefore needs to consider the amount of insulation required to control both heat loss and condensation.In the case of a flat roof, insulation is usually in the form of either a rigid board above the deck, or a fibrous quilt immediately above the ceiling, depending on the type of roof construction.There are three recognised designs of flat roof construction; warm, cold, and inverted.Warm RofIn a warm roof construction the principal thermal insulation layer is located above the structural decking, resulting in the structural deck and support structure being at a temperature close to that of the interior of the building. It is necessary to incorporate a vapour control layer beneath the insulation in order to prevent moisture vapour being forced into the insulation through thermal pressure from within the building. The waterproofing membranes are placed over the insulation to completely encapsulate it.There is no requirement for roof void ventilation, and cold bridging through the system is easier to eliminate because there are no interruptions from the structural supports as there is in a cold roof construction.Although this type of construction is normally continuously supported, it can also provide a flat and stable structure directly over most profiled metal decking and is generally recommended for all flat roof applications due to the simplicity of its design.1234561. Waterproofing 2. Rigid Insulation3. Vapour Control Layer4. Structural Deck (eg plywood)5. Roof Void6. Ceiling7. Support StructureCOLD RofIn cold roof construction, the principal thermal insulation layer is located below the structural decking. The concept for this type of design is usually associated with roof constructions having independent ceilings to support the insulation. Adequate ventilation must be provided between the insulation and the underside of the roof deck to prevent the risk of interstitial condensation forming within the construction.A cold roof design is not generally recommended for new build flat roof applications due to the added requirement for roof void ventilation and the difficulties in preventing cold bridging through the system.If an existing cold roof is to be refurbished, consideration should be given to converting the design to a warm roof, or incorporating new insulation into the roofing system to improve thermal performance. However, if the latter is the case, thermal calculations will be required in order to analyse the likelihood of condensation formation.1234561. Waterproofing2. Structural Deck (eg plywood)3. Support Structure4. Ventilated Ceiling Void5. Quilt Insulation6. Ceiling7. Cross Ventilation77Manchester UniversityTypical Bauder warm roofbauder.ie200

Inverted Rof (Upside Down Roof)In an inverted roof construction, the principal thermal insulation layer is located not only above the roof structure but also above the waterproofing, resulting in the waterproofing, structural deck and support structure being at a temperature close to that of the interior of the building. No vapour control layer is required.This type of construction is generally only used for flat roof applications to concrete support structures due to the weight loading of the ballast that becomes necessary to restrain the insulation against wind uplift and flotation.123451. Surfacing / Ballast (eg paving or pebbles)2. Filtration Layer / Vapour Permeable Membrane3. Inverted Roof Insulation Boards (eg extruded polystyrene)4. Waterproofing System5. Structural Deck (eg concrete)INSULATIONThe designer should determine the type of insulation required for the construction by consideration of the factors listed below:1. Required thermal performance ('U-value') of the roof. 2. The build-up thickness that can be accommodated at roof level. 3. Imposed weight loading to the deck structure.4. Compressive strength required (the ability of the insulation to withstand loads applied directly onto the roof system surface).5. The level and type of traffic that the roof will experience both during and after construction.6. Compatibility with other roofing components.7. Required fire resistance.8. Required acoustic performance. 9. Environmental properties.Bauder manufactures rigid urethane foam insulation products for use within Bauder warm roof systems to provide a totally compatible system. This product has been specifically chosen for the benefits it provides, however, we are able to provide certain other insulation materials as part of the system should this be considered preferable. When inverted design is required, we can provide Bauder XPS or BauderJFRI insulation along with their associated Vapour Permeable Membrane.CONDENSATIONThe temperature at which air becomes fully saturated with moisture (100% RH) is called the dew point. When warm moist air meets a cold surface it is cooled, and if its temperature drops below the dew point it will give up moisture in the form of surface condensation.The air within a building normally contains more water vapour than the external air and so therefore has a higher vapour pressure. This creates a vapour drive from the areas of high pressure to areas of low pressure and water vapour will try to escape by all available routes to the low pressure conditions outside the building.Moisture vapour is also present in all the permeable materials of a building, including the roof construction, and as the vapour pressure inside a building is continually changing, there is a constant flow of water vapour in and out of the roofing materials.In cold weather the temperature under the waterproofing will fall and can create a zone in the roof structure where the temperatures are below the dew point. Moisture will condense in this zone to form interstitial condensation.The incorporation of adequate insulation and ventilation in the roof void of a cold roof construction, or sufficient insulation and vapour barrier in a warm roof construction, will prevent the formation of interstitial condensation in the normal range of environmental conditions experienced.The Bauder Technical Services Team is always available for free 'U' value and condensation risk calculations, or for advice on any particular project.Building RegulationsMinimum levels of insulation required in flat roof constructions is governed by Building Regulations. These levels are rising on an ever increasing scale as the Government strives to meet its targets for reducing CO2 emissions. Along with increased insulation levels is a requirement for attention to construction details in order to reduce thermal bridging and air leakage where the various elements of a building meet. Guidance on detail design is given by 'Accredited Construction Details' which is available from www.planningportal.gov.uk201 bauder.co.ukSpecification SupportNBS SPECIFICATIONSwww.bauder.co.uk/technical-centreTECHNICAL HELPLINET: +44 (0)1473 257671E: technical@bauder.co.ukFLAT ROOFDESIGN GUIDE