page 1 page 2 page 3 page 4 page 5 page 6 page 7 page 8 page 9 page 10 page 11 page 12 page 13 page 14 page 15 page 16 page 17 page 18 page 19 page 20 page 21 page 22 page 23 page 24 page 25 page 26 page 27 page 28 page 29 page 30 page 31 page 32 page 33 page 34 page 35 page 36 page 37 page 38 page 39 page 40 page 41 page 42 page 43 page 44 page 45 page 46 page 47 page 48 page 49 page 50 page 51 page 52 page 53 page 54 page 55 page 56 page 57 page 58 page 59 page 60 page 61 page 62 page 63 page 64 page 65 page 66 page 67 page 68 page 69 page 70 page 71 page 72 page 73 page 74 page 75 page 76 page 77 page 78 page 79 page 80 page 81 page 82 page 83 page 84 page 85 page 86 page 87 page 88 page 89 page 90 page 91 page 92 page 93 page 94 page 95 page 96 page 97 page 98 page 99 page 100 page 101 page 102 page 103 page 104 page 105 page 106 page 107 page 108 page 109 page 110 page 111 page 112 page 113 page 114 page 115 page 116 page 117 page 118 page 119 page 120 page 121 page 122 page 123 page 124 page 125 page 126 page 127 page 128 page 129 page 130 page 131 page 132 page 133 page 134 page 135 page 136 page 137 page 138 page 139 page 140 page 141 page 142 page 143 page 144 page 145 page 146 page 147 page 148 page 149 page 150 page 151 page 152 page 153 page 154 page 155 page 156 page 157 page 158 page 159 page 160 page 161 page 162 page 163 page 164 page 165 page 166 page 167 page 168 page 169 page 170 page 171 page 172 page 173 page 174 page 175 page 176 page 177 page 178 page 179 page 180 page 181 page 182 page 183 page 184 page 185 page 186 page 187 page 188 page 189 page 190 page 191 page 192 page 193 page 194 page 195 page 196 page 197 page 198 page 199 page 200 page 201 page 202 page 203 page 204 page 205 page 206 page 207 page 208 page 209 page 210 page 211 page 212 page 213 page 214 page 215 page 216
|
THERMAL DESIGNThermal design is concerned with the flow of both heat and water vapour through the roof construction and their subsequent effect on the performance of the roof and the various components in the system. The designer therefore needs to consider the amount of insulation required to control both heat loss and condensation.In the case of a flat roof, insulation is usually in the form of either a rigid board above the deck, or a fibrous quilt immediately above the ceiling, depending on the type of roof construction.There are three recognised designs of flat roof construction; warm, cold, and inverted.Warm RofIn a warm roof construction the principal thermal insulation layer is located above the structural decking, resulting in the structural deck and support structure being at a temperature close to that of the interior of the building. It is necessary to incorporate a vapour control layer beneath the insulation in order to prevent moisture vapour being forced into the insulation through thermal pressure from within the building. The waterproofing membranes are placed over the insulation to completely encapsulate it.There is no requirement for roof void ventilation, and cold bridging through the system is easier to eliminate because there are no interruptions from the structural supports as there is in a cold roof construction.Although this type of construction is normally continuously supported, it can also provide a flat and stable structure directly over most profiled metal decking and is generally recommended for all flat roof applications due to the simplicity of its design.1234561. Waterproofing 2. Rigid Insulation3. Vapour Control Layer4. Structural Deck (eg plywood)5. Roof Void6. Ceiling7. Support StructureCOLD RofIn cold roof construction, the principal thermal insulation layer is located below the structural decking. The concept for this type of design is usually associated with roof constructions having independent ceilings to support the insulation. Adequate ventilation must be provided between the insulation and the underside of the roof deck to prevent the risk of interstitial condensation forming within the construction.A cold roof design is not generally recommended for new build flat roof applications due to the added requirement for roof void ventilation and the difficulties in preventing cold bridging through the system.If an existing cold roof is to be refurbished, consideration should be given to converting the design to a warm roof, or incorporating new insulation into the roofing system to improve thermal performance. However, if the latter is the case, thermal calculations will be required in order to analyse the likelihood of condensation formation.1234561. Waterproofing2. Structural Deck (eg plywood)3. Support Structure4. Ventilated Ceiling Void5. Quilt Insulation6. Ceiling7. Cross Ventilation77Manchester UniversityTypical Bauder warm roofbauder.ie200 Inverted Rof (Upside Down Roof)In an inverted roof construction, the principal thermal insulation layer is located not only above the roof structure but also above the waterproofing, resulting in the waterproofing, structural deck and support structure being at a temperature close to that of the interior of the building. No vapour control layer is required.This type of construction is generally only used for flat roof applications to concrete support structures due to the weight loading of the ballast that becomes necessary to restrain the insulation against wind uplift and flotation.123451. Surfacing / Ballast (eg paving or pebbles)2. Filtration Layer / Vapour Permeable Membrane3. Inverted Roof Insulation Boards (eg extruded polystyrene)4. Waterproofing System5. Structural Deck (eg concrete)INSULATIONThe designer should determine the type of insulation required for the construction by consideration of the factors listed below:1. Required thermal performance ('U-value') of the roof. 2. The build-up thickness that can be accommodated at roof level. 3. Imposed weight loading to the deck structure.4. Compressive strength required (the ability of the insulation to withstand loads applied directly onto the roof system surface).5. The level and type of traffic that the roof will experience both during and after construction.6. Compatibility with other roofing components.7. Required fire resistance.8. Required acoustic performance. 9. Environmental properties.Bauder manufactures rigid urethane foam insulation products for use within Bauder warm roof systems to provide a totally compatible system. This product has been specifically chosen for the benefits it provides, however, we are able to provide certain other insulation materials as part of the system should this be considered preferable. When inverted design is required, we can provide Bauder XPS or BauderJFRI insulation along with their associated Vapour Permeable Membrane.CONDENSATIONThe temperature at which air becomes fully saturated with moisture (100% RH) is called the dew point. When warm moist air meets a cold surface it is cooled, and if its temperature drops below the dew point it will give up moisture in the form of surface condensation.The air within a building normally contains more water vapour than the external air and so therefore has a higher vapour pressure. This creates a vapour drive from the areas of high pressure to areas of low pressure and water vapour will try to escape by all available routes to the low pressure conditions outside the building.Moisture vapour is also present in all the permeable materials of a building, including the roof construction, and as the vapour pressure inside a building is continually changing, there is a constant flow of water vapour in and out of the roofing materials.In cold weather the temperature under the waterproofing will fall and can create a zone in the roof structure where the temperatures are below the dew point. Moisture will condense in this zone to form interstitial condensation.The incorporation of adequate insulation and ventilation in the roof void of a cold roof construction, or sufficient insulation and vapour barrier in a warm roof construction, will prevent the formation of interstitial condensation in the normal range of environmental conditions experienced.The Bauder Technical Services Team is always available for free 'U' value and condensation risk calculations, or for advice on any particular project.Building RegulationsMinimum levels of insulation required in flat roof constructions is governed by Building Regulations. These levels are rising on an ever increasing scale as the Government strives to meet its targets for reducing CO2 emissions. Along with increased insulation levels is a requirement for attention to construction details in order to reduce thermal bridging and air leakage where the various elements of a building meet. Guidance on detail design is given by 'Accredited Construction Details' which is available from www.planningportal.gov.uk201 bauder.co.ukSpecification SupportNBS SPECIFICATIONSwww.bauder.co.uk/technical-centreTECHNICAL HELPLINET: +44 (0)1473 257671E: technical@bauder.co.ukFLAT ROOFDESIGN GUIDE |